8 Fibers, MTP to LC/SC/ST/FC, OM3 Fiber, 12 Standard - MTP Breakout Harness Cable
MTP is the high dense degree of optical fiber pre-connect system,which is generally use in three areas: Fiber-Mart's MTP fiber patch cable is compliant to IEC-61754-7 and TIA-604-5(FOCIS-5) standard. It can be widely used for
10G upgrade to 40G/100G data center. MTP Connector
Pre-terminated MTP Technology-Polarity Type B (Cross)
For example:
|
MTP 8 Fiber Distribution
Notes:
Please kindly to choice the best one for your project from above the two kinds of 8 fiber MTP harness cable array methods.
In the 40/100GbE project, 8 optical fibers are required.
Assembly Structure Illustration
12-Fiber Mini-Core Cable structure
MTP Hybrid Harnesses Fiber Patch Cables are terminated with MTP connector on one end and other end with LC, FC, SC, ST, or MTRJ connectors to meet a variety of fiber cabling requirements.
1.The default diameter of the MTP cable is 3.0mm.
2.The diameter of branch cable could be choose as 0.9mm,2.0mm,please kindly contact us at [email protected] for other diameter standard.
3.Fiber-Mart can also custom the pulling eyes, welcome to contact us if you need.
MTP/MPO Machinery & Testing Equipment
1 | Our adopt industry's leading high-performance polishing machine, and complemented by precision plates holders designed for MT ferrules. |
2 | The industry leading device of 3D interferometer provides verification of MTP/MPO polishing process, the interferometer making all parameters of hte polished MT ferrule complies and exceeds industry standards. |
3 | After the 3D interference detection, the flexibility of the tester provides the the complete spectrum of optical testing required for complex and high fiber count cable assemblies. |
MTP Termination
Type | Single mode | Single mode | Multi mode | |||
(APC polish) | (PC polish) | (PC polish) | ||||
Fiber count | 8, 12, 24 etc. | 8, 12, 24 etc. | 8, 12, 24 etc. | |||
Fiber type | G652D, G657A1 etc. | G652D, G657A1 etc. | OM1, OM2, OM3 etc. | |||
Maximum Insertion Loss | Elite | Standard | Elite | Standard | Elite | Standard |
Low Loss | Low Loss | Low Loss | ||||
≤0.35 dB | ≤0.70 dB | ≤0.35 dB | ≤0.70 dB | ≤0.35dB | ≤0.60dB | |
Return Loss | ≥60 dB | ≥60 dB | N/A | |||
Durability | ≥500 times | ≥500 times | ≥500 times | |||
Operating Temperature | -40℃ ~ +80℃ | -40℃~ +80℃ | -40℃~ +80℃ | |||
Test Wavelength | 1310nm | 1310nm | 850nm |
Common Termination
Type | Single mode | Multi mode | |
(UPC APC polish) | (UPC polish) | ||
Insertion Loss | ≤0.30dB | ≤0.30dB | |
Return Loss | ≥55 dB | ≥60 dB | ≥25 dB |
Durability | ≥1000 times | ≥1000 times | |
Operating Temperature | -40℃ ~ +80℃ | -40℃ ~ +80℃ | |
Test Wavelength | 1310nm | 850nm |
Note: Maximum Bandwidths of Different Multimode Fibers
OM1 – 62.5 um Core – 10GBit up to 33 meters, gigabit up to 300m
OM2 – 50 um Core – 10GBit up to 82 meters,gigabit up to 500m
OM3 – 50 um Core, Laser Optimized – 10GBit up to 300 meters,gigabit up to 1000m
OM4 – 50 um Core, Laser Optimized – 10GBit up to 550 meters,gigabit up to 1000m
Make To Order
Fiber Type | Fiber Standard | Fiber Count | Cable Type | Termination | Cable Length(m) | Breakout Length 1&2(Inches) | Breakout Termination | Polish Type |
OM4 OM3 OS1/2 OM2 OM1 |
12 Fibers | 8~144 Fibers |
LSZH Bunch LSZH Ribbon Riser Bunch Riser Ribbon |
First Connector: MTP Female MTP Male |
1~999 |
12~99 (36" is typical) |
3.0mm |
UPC APC |
24 Fibers | 24~144 Fibers |
Second Connector: LC Duplex/LC Simplex SC Duplex/SC Simplex ST Duplex/ST Simplex FC Duplex/FC Simplex |
0.9μm (standard) 2.0mm 3.0mm |
Note:Polishing connector (A): PC (multimode), APC 8° (single-mode)
Polishing connector (B) : PC (multimode/single-mode), APC 8° (single-mode)
Furcation length (B): 0.5m/0.3m for 1m total length
Type of protection connector: IP20
Patch cord Type: Minicore cable, round