Compras recientes
|
El mejor cable de conexión de fibra multimodo Simplex 50/125 de MU-MU Plenum (OFNP) Producto para usted
|
According to National Electric Code (NEC), a plenum is a "compartment or chamber to which one or more air ducts are connected and forms part of the air distribution system." that is to say, as a plenum, the space above an acoustic tile ceiling would have to extend above other rooms in the same building or be open to ducts connecting it to other parts of the building. The concern is that during a fire, if there is burning material in a plenum air space, smoke and fumes can travel through air ducts to the whole building. For this reason, there are codes to restrict the types of materials (such as cables) that can be placed in the plenum. |
Caracteristicas
Conector: MU-MU
Strand Count: Simplex (1-Strand)
Núcleo / diámetro del revestimiento: 50 / 125um
Chaqueta: OFNP (Plenum-rated)
Inmune a la interferencia eléctrica
100% inspeccionado ópticamente y probado para pérdida de inserción
Atenuación: 850 nm: 3,5 dB / km o a 1300 nm: 1,0 dB / km
RoHS
Presupuesto
Specification | Unit | FC, SC, LC/Armored Cables | ST, MU | MT-RJ, MPO | E2000 | ||||||||
Single-mode | Multi-mode | Single-mode | Multi-mode | Single-mode | Multi-mode | Single-mode | |||||||
PC | UPC | APC | PC | PC | UPC | PC | PC | UPC | PC | PC | APC | ||
Insertion loss | dB | ≤0.3 | ≤0.2 | ≤0.3 | ≤0.2 | ≤0.3 | ≤0.2 | ≤0.2 | ≤0.3 | ≤0.2 | ≤0.2 | ≤0.3 | ≤0.3 |
Return loss | dB | ≥45 | ≥50 | ≥60 | ≥30 | ≥45 | ≥50 | ≥30 | ≥45 | ≥50 | ≥35 | ≥55 | ≥75 |
Wavelength | nm | 850,1310 | 850,1310 | 850,1310 | 850,1310 | ||||||||
Interchangeability | dB | ≤0.2 | ≤0.2 | ≤0.2 | ≤0.2 | ||||||||
Vibration | dB | ≤0.2 | ≤0.2 | ≤0.2 | ≤0.2 | ||||||||
Operating temperature | ℃ | -40~75 | -40~75 | -40~75 | -40~75 | ||||||||
Storage temperature | ℃ | -45~85 | -45~85 | -45~85 | -45~85 | ||||||||
Cable diameter | mm | φ3.0,φ2.0,φ0.9 | φ3.0,φ2.0,φ0.9 | φ3.0,φ2.0,φ0.9 | φ3.0,φ2.0,φ0.9 |
OEM personalizado
Fiber-Mart es fabricante y proveedor de cable de fibra óptica. Si tiene algún requisito especial, contáctenos por correo electrónico a [email protected] o llame al +1-205-282-9089.
Nota:
A pesar de que el Código Eléctrico Nacional puede permitir el cable no plenum, la decisión final corresponde a su jefe de bomberos local. La mayoría de las ciudades adoptan los códigos nacionales como propios sin revisión, pero algunas ciudades los modifican o amplían y requieren cable con plenum en todas las situaciones. Independientemente del código o su interpretación, su Jefe de Bomberos toma la decisión final. Le recomendamos que se contacte con su Jefe de Bomberos si tiene alguna pregunta.