Meilleur produit de câble de correction de fibre multi-mode de Simplex 50/125 de MU-MU Plenum (OFNP) pour vous
|
According to National Electric Code (NEC), a plenum is a "compartment or chamber to which one or more air ducts are connected and forms part of the air distribution system." that is to say, as a plenum, the space above an acoustic tile ceiling would have to extend above other rooms in the same building or be open to ducts connecting it to other parts of the building. The concern is that during a fire, if there is burning material in a plenum air space, smoke and fumes can travel through air ducts to the whole building. For this reason, there are codes to restrict the types of materials (such as cables) that can be placed in the plenum. |
Caractéristiques
Connecteur: MU-MU
Nombre de brins: Simplex (1 brin)
Diamètre du noyau / revêtement: 50 / 125um
Veste: OFNP (classé Plénum)
Immunité aux interférences électriques
100% optiquement inspecté et testé pour la perte d'insertion
Atténuation: 850 nm: 3,5 dB / km ou à 1300 nm: 1,0 dB / km
Conforme RoHS
Caractéristiques
Specification | Unit | FC, SC, LC/Armored Cables | ST, MU | MT-RJ, MPO | E2000 | ||||||||
Single-mode | Multi-mode | Single-mode | Multi-mode | Single-mode | Multi-mode | Single-mode | |||||||
PC | UPC | APC | PC | PC | UPC | PC | PC | UPC | PC | PC | APC | ||
Insertion loss | dB | ≤0.3 | ≤0.2 | ≤0.3 | ≤0.2 | ≤0.3 | ≤0.2 | ≤0.2 | ≤0.3 | ≤0.2 | ≤0.2 | ≤0.3 | ≤0.3 |
Return loss | dB | ≥45 | ≥50 | ≥60 | ≥30 | ≥45 | ≥50 | ≥30 | ≥45 | ≥50 | ≥35 | ≥55 | ≥75 |
Wavelength | nm | 850,1310 | 850,1310 | 850,1310 | 850,1310 | ||||||||
Interchangeability | dB | ≤0.2 | ≤0.2 | ≤0.2 | ≤0.2 | ||||||||
Vibration | dB | ≤0.2 | ≤0.2 | ≤0.2 | ≤0.2 | ||||||||
Operating temperature | ℃ | -40~75 | -40~75 | -40~75 | -40~75 | ||||||||
Storage temperature | ℃ | -45~85 | -45~85 | -45~85 | -45~85 | ||||||||
Cable diameter | mm | φ3.0,φ2.0,φ0.9 | φ3.0,φ2.0,φ0.9 | φ3.0,φ2.0,φ0.9 | φ3.0,φ2.0,φ0.9 |
OEM personnalisé
Fibre-Mart est fabricant et fournisseur de câbles à fibres optiques. Si vous avez des exigences particulières, veuillez nous contacter par email à [email protected] ou appeler au +1-205-282-9089.
Remarque:
Bien que le Code national de l'électricité puisse autoriser l'utilisation de câbles sans plénum, la décision finale appartient à votre pompier local. La plupart des villes adoptent les codes nationaux sans les réviser, mais certaines villes les modifient ou les élargissent et nécessitent une connexion par câble dans toutes les situations. Quel que soit le code ou son interprétation, votre commissaire aux incendies prend la décision finale. Nous vous recommandons de contacter votre pompier si vous avez des questions.