According to National Electric Code (NEC), a plenum is a "compartment or chamber to which one or more air ducts are connected and forms part of the air distribution system." that is to say, as a plenum, the space above an acoustic tile ceiling would have to extend above other rooms in the same building or be open to ducts connecting it to other parts of the building. The concern is that during a fire, if there is burning material in a plenum air space, smoke and fumes can travel through air ducts to the whole building. For this reason, there are codes to restrict the types of materials (such as cables) that can be placed in the plenum. |
Características
Conector: MU-MU
Contagem de Strand: Simplex (1-Strand)
Diâmetro do núcleo / revestimento: 50 / 125um
Jaqueta: OFNP (Plenum-rated)
Imune a interferências elétricas
100% inspecionado oticamente e testado para perda de inserção
Atenuação: 850nm: 3,5 dB / km ou a 1300nm: 1,0 dB / km
Em conformidade com a RoHS
Especificações
Specification | Unit | FC, SC, LC/Armored Cables | ST, MU | MT-RJ, MPO | E2000 | ||||||||
Single-mode | Multi-mode | Single-mode | Multi-mode | Single-mode | Multi-mode | Single-mode | |||||||
PC | UPC | APC | PC | PC | UPC | PC | PC | UPC | PC | PC | APC | ||
Insertion loss | dB | ≤0.3 | ≤0.2 | ≤0.3 | ≤0.2 | ≤0.3 | ≤0.2 | ≤0.2 | ≤0.3 | ≤0.2 | ≤0.2 | ≤0.3 | ≤0.3 |
Return loss | dB | ≥45 | ≥50 | ≥60 | ≥30 | ≥45 | ≥50 | ≥30 | ≥45 | ≥50 | ≥35 | ≥55 | ≥75 |
Wavelength | nm | 850,1310 | 850,1310 | 850,1310 | 850,1310 | ||||||||
Interchangeability | dB | ≤0.2 | ≤0.2 | ≤0.2 | ≤0.2 | ||||||||
Vibration | dB | ≤0.2 | ≤0.2 | ≤0.2 | ≤0.2 | ||||||||
Operating temperature | ℃ | -40~75 | -40~75 | -40~75 | -40~75 | ||||||||
Storage temperature | ℃ | -45~85 | -45~85 | -45~85 | -45~85 | ||||||||
Cable diameter | mm | φ3.0,φ2.0,φ0.9 | φ3.0,φ2.0,φ0.9 | φ3.0,φ2.0,φ0.9 | φ3.0,φ2.0,φ0.9 |
OEM personalizado
A Fiber-Mart é fabricante e fornecedora de cabos de fibra ótica. Se você tiver alguma exigência especial, entre em contato conosco por e-mail para [email protected] ou ligue para +1-205-282-9089.
Nota:
Embora o National Electric Code possa permitir cabo não-plenum, a decisão final é do seu Fire Marshall local. A maioria das cidades adota os códigos nacionais como seus, sem revisão, mas algumas cidades modificam ou expandem os códigos e exigem cabos com classificação plenum em todas as situações. Independentemente do código ou da sua interpretação, o seu Fire Marshall toma a decisão final. Recomendamos que você entre em contato com seu Fire Marshall se tiver dúvidas.