E2000/UPC-E2000/UPC Plenum (OFNP) Simplex 9/125 Câble de raccordement de Fibre monomode---MEILLEUR PRIX
Plenum-rated fiber optic cables are different from other types of cabling by the special types of plastics used in the fiber optic cable jackets. Because plenum cables are routed through air circulation spaces, which contain very few fire barriers, they need to be coated in flame-retardant, low smoke materials. These plastics offer good resistance against possible fire, and in the event that they do begin to burn, they will not emit large quantities of harmful fumes.
Fiber-Mart’s Plenum Fire Rated fiber cables provide a low cost option for gigabit Ethernet network applications. Plenum rated cables are used for running in walls and air plenums without the use of conduit. Each cable is tested for optical integrity and loss prior to packaging to ensure proper data transmission. The durable rubber boots protects against damage typical in busy data racks and each end is properly labeled for easy identification.
Applications
Déploiements de réseau de fibre
Fast Ethernet
Gigabit Ethernet
Infiniband
AU M
Autres applications de données nécessitant des taux de transfert élevés
|
Selon le National Electric Code (NEC), un plénum est un «compartiment ou une chambre à laquelle un ou plusieurs conduits d'air sont connectés et font partie du système de distribution d'air». c'est-à-dire, en tant que plénum, l'espace au-dessus d'un plafond de tuiles acoustiques devrait s'étendre au-dessus d'autres pièces dans le même bâtiment ou être ouvert à des conduits le reliant à d'autres parties du bâtiment. Le problème est que, lors d'un incendie, s'il y a du matériel qui brûle dans l'espace d'air du plénum, la fumée et les vapeurs peuvent traverser les conduits d'air jusqu'à l'ensemble du bâtiment. Pour cette raison, il existe des codes pour restreindre les types de matériaux (tels que les câbles) qui peuvent être placés dans le plénum. |
Caractéristiques
Connecteur: E2000 / UPC-E2000 / UPC
Nombre de brins: Simplex (1 brin)
Diamètre de noyau / revêtement: 9 / 125um
Veste: OFNP (Plenum-rated)
Immunisé contre les interférences électriques
100% inspecté optiquement et testé pour la perte d'insertion
Atténuation: 850nm: 3,5 dB / km ou à 1300nm: 1,0 dB / km
Conforme RoHS
Caractéristiques
Specification |
Unit |
FC, SC, LC/Armored Cables |
ST, MU |
MT-RJ, MPO |
E2000 |
Single-mode |
Multi-mode |
Single-mode |
Multi-mode |
Single-mode |
Multi-mode |
Single-mode |
PC |
UPC |
APC |
PC |
PC |
UPC |
PC |
PC |
UPC |
PC |
PC |
APC |
Insertion loss |
dB |
≤0.3 |
≤0.2 |
≤0.3 |
≤0.2 |
≤0.3 |
≤0.2 |
≤0.2 |
≤0.3 |
≤0.2 |
≤0.2 |
≤0.3 |
≤0.3 |
Return loss |
dB |
≥45 |
≥50 |
≥60 |
≥30 |
≥45 |
≥50 |
≥30 |
≥45 |
≥50 |
≥35 |
≥55 |
≥75 |
Wavelength |
nm |
1310,1550 |
1310,1550 |
1310,1550 |
1310,1550 |
Interchangeability |
dB |
≤0.2 |
≤0.2 |
≤0.2 |
≤0.2 |
Vibration |
dB |
≤0.2 |
≤0.2 |
≤0.2 |
≤0.2 |
Operating temperature |
℃ |
-40~75 |
-40~75 |
-40~75 |
-40~75 |
Storage temperature |
℃ |
-45~85 |
-45~85 |
-45~85 |
-45~85 |
Cable diameter |
mm |
φ3.0,φ2.0,φ0.9 |
φ3.0,φ2.0,φ0.9 |
φ3.0,φ2.0,φ0.9 |
φ3.0,φ2.0,φ0.9 |
OEM personnalisé
Fiber-Mart sont fabricant et fournisseur de câbles à fibres optiques. Si vous avez des besoins particuliers, veuillez nous contacter par email à [email protected] ou appeler au +1-205-282-9089.
Remarque:
Bien que le National Electric Code puisse autoriser un câble autre que le plenum, la décision finale revient au prévôt des incendies local. La plupart des villes adoptent les codes nationaux comme étant les leurs sans révision, mais certaines villes les modifient ou les élargissent et requièrent un câble d'accès au plénum dans toutes les situations. Quel que soit le code ou son interprétation, votre commissaire aux incendies prend la décision finale. Nous vous recommandons de contacter votre commissaire des incendies si vous avez des questions.