Fluke Test Equipment Operation Instruction

  • Fluke Test Equipment Operation Instruction Fiber-Mart.com
  • Post on Thursday 18 December, 2014
  • 107
  • 0




Fluke test equipments are so widely used by many maintenance works, technicians, engineers or scientific researchers, considering that the specific operation documents may be not familiar to all of them, this article is written to tell something about the operation instruction of Fluke test equipment, hope it will do help for readers.

 
Initialization steps before using Fluke testers:

Charge: Fluke DTX series host, auxiliary power supply adapter for charging until the battery indicator light turns green.
 
Set the language: Turn to host knob of the Fluke DTX series to the Set Up status, turn on the test by pressing the lower right green button, use the↓arrow and select the third Instrument setting, the machine setting, press Enter to enter the parameter setting. First, select and click the → arrow, when enter the second page, press↓arrow to select English and enter. After finishing the language setting, move to the next step.
 
Self-calibration: Take fluke DTX series Cat6A/Class EA permanent link adapter installed on the host, auxiliary equipment installed on the Cat6A/Class EA channel adapter. Then plug the end of the permanent link adapter in Cat6A/Class EA channel adapter, open the auxiliary power, after the self-testing of the auxiliary, the PASS lights off after normal auxiliary. SPECIAL FUNCTIONS stalls, turn on the console, the host, auxiliary software, hardware and test standard version (auxiliary information only when the the auxiliary boot and host connection), operation interface after self testing, select the first set the reference (If choose the wrong EXIT to exit the repeat), press ENTER key and the TEST button to star sef-calibration, when it dispay “setting the reference has completed”, it indicate that the self-calibration has successfully completed.
 
Set the basic parameters of the Fluke tester:
 
Action: Go to the Fluke DTX Series host knob "SET UP" stalls, use "↑ ↓" to choose the third set the value of the instrument, press "ENTER" to enter the parameter setting, you can press the "← →" flip "↑ ↓" to select your desired setting parameters, press ENTER to enter the parameter changes, you need to use "↑ ↓" to select parameter settings selected Press ENTER to select and complete the parameter settings.
 
Fluke tester testing process:
1.Determined according to the needs of the test limit and cable type: channel test or permanent link test? CAT5E or CAT6 or other?
2.After shutdown, install the corresponding adapter of different testing standard in the host and auxiliary, such as select TIA CAT5E CHANNEL testing standards, the host and auxiliary will be installed in DTX-CHA002 Channel adapters, if selecting the TIA CAT6A PERM.LINK, the permanent link test standard, the host and auxiliary should be respectively installed with a DTX-PLA002 permanent link adapters.
3.Parameters that may be often required to change
Dial to "SET UP" stalls, selecting the twisted pair, press ENTER to enter: Type of cable: press ENTER and then press the ↑ ↓ select the type of cable you want to test, for example I want to test over Category 5 twisted-pair UTP Press ENTER ENTER ↑ ↓ Select Cat 5e UTP press ENTER to return.
Test limit: Press ENTER and then press ↑ ↓ to select the testing standard for the type of cable you want to test, press F1 to select more, generally option for the standard in TIA, for example,  if I was testing over Category 5 twisted pair cable, Press ENTER to see if there are TIA Cat 5e Channel or not, if not, press F1 to enter more selection, select TIA and press Enter, select TIA Cat 5e Channel and press ENTER to confirm return.
4.Connect all the equipments that need to be tested with the corresponding adapter. Press "TEST" to start testing, after a while, it will display FASS or FAIL.
 
View test results and check failure
 
After the testing, it will automatically show the result. Use the ENTER key to view the parameter details, F2 for previous page, F3 for the next page, press EXIT and press F3 to view the memory data storage. If the testing result is FAIL, you can check the failure details by selecting X.
 
Saving the Fluke test result
1.Select SAVE key to store the test result, use "← → ↑ ↓" key or ← → to move the cursor (F1 and F2 keys), F3 key to select the name you want to use, such as 01 and press SAVE to store.
2.Replace the special measurement products and re-start the test by pressing the TEST to test new data, press again SAVE to store data, the machine will automatically name the data by pulsing 1, which is 02, press to save if you agree with the name. Repeat the above operation steps to finish all the testing for your products. If the memory space is not enough, you need to download the data and re-start the steps above.

Fluke Test Equipment includes electrical test equipment, environmental test equipment, mechanical test equipment and more. For more other testers info, please focus on Fiber Optic Tester & Tools, there are many useful testing and tools tutorial in this part. Fiber-Mart not only provide the fiber tester, but also offer some fiber optic tools, such as crimping tool, wire cutter and punch down tool.


Featured Products
Optical Switch Supply

Optical switch supply from Fiber-Mart

Non-latching, latching, single-mode and multimode optical switch
Compatible SFP+ Supply

Compatible SFP+ supply from Fiber-Mart

Customize Compatible SFP+ Module to fit your specific requirements
SDI&HDMI&VGA Fiber Converter

SDI&HDMI&VGA Fiber Converter on Fiber-Mart

SDI, 3G-SDI, HD-SDI, and SDI-HDMI over fiber video converter.
Email for Technical Tips
-consulting for technical supports or relevent product buying guide
Email for Sales

Comments: (0)

No comments have been posted yet.

Leave a Comment
You must be logged in to submit a comment.
Copyright © 2009-2024 Fiber-MART.COM All Rights Reserved. Privacy Notice. Terms of Service
Fibermart ISO9001Fibermart Secure Certificate
Product Tags: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Email us